Medium voltage cables

Installs SIA supplies different types of medium voltage power cables depending on specific requirements and site conditions.

Middle voltage cables are applied for transmission and distribution installations, electric power stations and industrial systems. The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits and shafts, over shelves and grills directly underground in ditch and outdoor shelter. The rated alternative voltage of 6, 10, 20 and 35 kV and frequency of 50 Hz for the networks with grounded and isolated neutral.

From a design point of view, medium-voltage cables are of two types: three-core cables and single-core cables. We propose cables to meet your high performance standards. The MV cables can be XLPE-insulated, copper wire screened, HFFR sheathed and meet Your requirements.

YKY(Fty)

3,6/6/6kV copper conductors, softened PVC insulation, return copper conductor superposed on insulation or filter sheath, softened PVC sheath, armoured with steel tapes (Ft), protective softened PVC sheath stamped on the armour (y)

YAKY(Fty)

3,6/6/6kV aluminium conductors, softened PVC insulation, return copper conductor, superposed on insulation or filter sheath, softened PVC sheath, armoured with steel tapes (Ft), protective softened PVC sheath stamped on the armour (y)

AYKCY, YAKY

3,6/6kV alumium conductor, PVC insulation, semiconducting tape, concentric copper conductor, tape and PVC sheath

CYKCY, YKY

3,6/6kV 3,6/6kV alumium conductor, PVC insulation, semiconducting tape, concentric copper conductor, tape and PVC sheath

NA2XSY, AXEKCY, YHAKXS

6/10, 8,7/15, 12/20kV, 18/30kV aliminum conductor, round stranded compacted (RMV), extruded inner semi-conductive layer, XLPE insulation, extruded outer semi-conductive layer, semiconducting tape, copper wire screen and copper tape counterhelix, non-conducting tape, PVC sheath

N2XSY, CXEKCY, YHKXS

6/10, 8,7/15, 12/20kV, 18/30kV copper conductor, round stranded compacted (RMV), extruded inner semi-conductive layer, XLPE insulation, extruded outer semi-conductive layer, semiconducting tape, copper wire screen and copper tape counterhelix, non-conducting tape, PE sheath

YHAKXS, YHKXS

8,7/15, 12/20kV, 18/30kV aluminum conductor, round stranded compacted (RMV), class 2, semi-conducting PE screen, XLPE insulation, semiconducting non-metallic tape, copper wire screen and copper tape counterhelix, non-conducting polyester tape, PVC sheath

XHAKXS, XRUHAKS

8,7/15, 12/20kV, 18/30kV aluminum conductor, round stranded compacted (RMV), extruded inner semi-conductive layer, XLPE insulation, semiconducting water blocking tape, copper wire screen and copper tape counterhelix, PE and thermoplastic sheath

AXQJ, AXLJ-F(O)

12kV, 24kV, 36kV copper wire screened and PE-sheathed cable with circular aluminum conductors, halogen-free, not flame retardant


Axclight-F(O) (TT)

12kV, 24kV, 36kV copper wire screened and HDPE-sheathed cable with circular aluminum conductors, halogen-free, not flame retardant, copper wire screen is corrosion protected

AXCEL

12, 20(24)kV aluminum stranded compacted round conductors, extruded semi-conducting screen, dry cured XLPE insulation, fire resistant

PAS

10/35kV aluminum alloy wires, stranded, compacted, round. Can contain steel reinforced aluminum messenger used as a neutral conductor, light stabilized XLPE insulation

AHXAMK-W, AHXMK-WTC

12, 20(24)kV watertight, circular stranded aluminium conductors, PEX-compund insulation, semiconducting compund insulation screen, aluminum/plastic laminate metallic screen, PVC or PE-compund sheath, fire resistant